Digitize Figure
Extract curve data from a published figure by manual point picking — SCLC J-V or FET transfer / conductance.
Step 1 — Upload Image
Step 2 — Axis Calibration
The platform first detects the frame and tick pixels automatically. If a provisional coloured anchor has no printed number, use its “Relocate” button and indicate a labelled tick; your click is snapped to exact detected geometry and is never used as a raw pixel coordinate.
How to fill or correct X₁ / X₂ / Y₁ / Y₂ · 坐标数值怎么填
Y₂ ●──── solid cyan frame ────┐
│ │
Y₁ ● │
└────●──────────────●──────┘
X₁ X₂- The coloured X anchors sit on the bottom axis; Y anchors sit on the selected side axis. A frame endpoint is valid only when that exact endpoint has an explicit printed numeric label.
- 填写彩色锚点所对应的印刷刻度值,不填青色方框边缘值,也不填曲线最大/最小值。
- 如果彩色锚点落在没有数字的次刻度,点击对应的 Relocate,再点击一个明确标有数字的刻度;系统会自动吸附,不采用手点像素。
- Log example: printed 10⁻¹⁰ → type 1e-10. Linear example: printed −40 → type -40.
Waiting for automatic geometry detection. The detector retries multiple contrast levels before asking for a clearer crop.
Step 3 — Extract Curve Points
You can trace the curve now and calibrate afterwards — the curve is captured in pixels, and every point's V/J value is re-derived the moment the axis values are set.
Hover to inspect the colour mask. Click the two usable endpoints of the same curve. The curve may occupy only part of the plot; there is no arbitrary plot-width percentage requirement. The hard anchors define the extracted interval: no points are guessed beyond them. If same-colour branches still collapse together, analysis is refused rather than averaged.
Manual clicks snap onto the nearest curve pixel, and a magnifier follows the cursor — a stroke only a few pixels wide cannot be hit by eye on a scaled-down image.
Step 4 — Analyze & Export
Why Send to Analyze is unavailable:
- SCLC log-log fitting needs at least 4 points with V > 0 and J > 0; currently 0.
- Automatic axis frame/tick detection has not succeeded.
- The four automatic calibration anchors are incomplete.
- Enter the values printed at X₁, X₂, Y₁ and Y₂.
This is the single final review action: it saves the visible calibration/trace diagnostics and carries the data to Analyze. If the cyan ticks, cyan frame or blue/cyan branch overlay are visibly wrong, retrace instead of submitting.
Export & Save
Provenance Metadata
Paper title, DOI, journal, year and figure number are optional. Missing them never blocks mobility calculation; the report will simply mark bibliographic provenance as incomplete.
Extracted points are saved as a draft in your browser. On reload you will be asked whether to restore it — it is never loaded silently, because a draft carries the previous figure's DOI and device parameters. Use Download to keep a permanent copy.
Extracted Points (0)
Complete axis calibration and switch to Pick mode.